The B6 Duo has all the power you need to get your batteries charged in no time! With two channels capable of 200W each, this charger packs quite a punch, especially with many new lipos capable of being charged at 5C rates. The B6 Duo can handle up to 6S of Lithium batteries per channel and up to 18 cells NiCd/NiMH. It also has an internal cell balancer, so you won't need an external balancer when charging Lithium batteries.
Optimized operating software
The B6 Duo features an AUTO function that controls the charge rate during charging and discharging. For Lithium batteries, this can prevent overcharging which may lead to an explosion due to the user's setting the charge rate improperly. It will disconnect the circuit automatically and initiate an alarm if there is any malfunction. All the operating modes of this charger are controlled through two way communication, between the charger and the battery to achieve maximum safety. All the settings can be configured by the user.
Internal independent lithium battery balancer
The B6 Duo employs an individual-cell-voltage balancer. It is not necessary to connect an external balancer for balance charging.
Balancing individual cells battery discharging
During the process of discharging, the B6 Duo can monitor and balance each cell of the battery individually. An error message will be indicated and the process will be ended automatically if the voltage of any single one cell is abnormal.
Adaptable to various types of lithium battery
The B6 Duo is adaptable to various types of Lithium batteries, such as Li-ion, LiPo and the new LiFe series of batteries.
"Fast" and "storage" mode of lithium battery
There are various methods of charging Lithium batteries. "Fast" charge reduces the charging time whereas "store charge" can control the final voltage of your battery. This method is best for long term storage and protects the useful life of the battery.
Maximum safety
Delta-peak sensitivity: The automatic charge termination program based on the principle of the Delta-peak voltage detection. When the battery's voltage exceeds the threshold, the process will be terminated automatically.
Automatic charging current limit
You can set the upper limit of the charge current when charging your NiCd or NiMH batteries. This is useful for NiMH batteries of low impedance and capacity in the 'AUTO' charging mode.
Temperature threshold
The batteries' internal chemical reaction can cause the temperature of the battery to rise during charging. If the temperature limit is reached (set by the user), the charging process will be terminated. This function is available by connecting an optional temperature probe, which is not included in with the charger.
Processing time limit
The user can set the maximum charging time. If the charging time exceeds the limit, the process will be terminated automatically when you set the maximum time for the charging mode.
Data store/load
The "Duo" can store data from ten different batteries. The user can set the charging / discharging parameters for a particular battery type and "call up" these settings to charge a battery without additional programming needed.
Cyclic charging/discharging
Batteries can be set to charge/ discharge for 5 cycles if needed.
Specs
Input voltage: 11-18 V DC
Max. Charge Power 2 x 200Watts
Max. Discharge Power 2 x 25Watts
Charge Current Range: 0.1-10A
Discharger Current Range: 0.1-5.0A
Current drain for balancing: Li-Po/Fe: 200mA/Cell, Li-ion/Poly cells: 1-6 cells, Ni-MH/NiCd cells: 1-18 cells
Pb battery voltage: 2-24V (1-10cells)
Dimensions: 200 x 135 x 57mm
Weight: 727g